eNOsyntex® is a mineral-oxide charge held in a polymer matrix, applied to the face of a finished textile that sits towards the body. In the far infrared it behaves almost as a blackbody: measured emittance ε ≈ 0.95, flat across 3–20 µm.
It absorbs the body’s own thermal emission and re-emits it at the same wavelengths, part of it back towards the skin. No energy source, no electronics, no active substance, nothing transferred through the skin. What the material does, it does radiatively.
In textile terms, eNOsyntex belongs to the family of so-called bioceramic materials, alongside Celliant and Emana. What sets it apart: it is applied to the finished fabric instead of being built into the fibre.
Every warm body radiates. What changes from one fabric to another is what happens to that radiation when it meets the layer closest to the skin. Every textile absorbs and re-emits part of it. The eNOsyntex layer does so close to the blackbody limit across the whole band, and gives a substantial share of it back towards the skin.
Skin at around 33 °C radiates continuously across roughly 3–20 µm, with a peak near 9.5 µm by Wien’s law. That radiation reaches the inner face of the garment whatever the wearer is doing.
With an emittance of about 0.95 across the whole band, the layer absorbs almost all the incident radiation and re-emits it at the same wavelengths. By Kirchhoff’s law it reflects only about 5 %: the mechanism is re-emission, not reflection.
Because the layer lies between the fabric and the skin, a substantial share of what it re-emits leaves towards the body. The effect exists only where the coating is applied, and only while the textile is worn. Coverage geometry is a design parameter.
The full data set, with method, bench conditions and raw curves, is released with the technical dossier under a mutual NDA. We expect it to be challenged, and we run the same characterisation on your own substrate during feasibility.
Each answer below is also in the written dossier, in the same terms.
Emittance is the ratio between the radiation a surface emits and the radiation a perfect blackbody would emit at the same temperature. A value of 0.95 sits within a few points of that ceiling. It is measured by infrared spectroscopy on coated textile samples across the 3–20 µm interval.
We report the behaviour across the whole band rather than a peak value at one wavelength, because a material can perform at 10 µm and collapse at 15 µm. Skin does not radiate at one wavelength, so a coating that performs over part of the band only works on part of the emission.
Measurements are run on the coated textile, not on the coating in isolation, so the value includes the real applied charge. The comparison product, the instrument, the operator and the raw curves are identified in the dossier.
For an opaque surface, emittance and reflectance add up to one. A surface that emits at 0.95 therefore reflects about 0.05. A true far-infrared mirror is an aluminised film, with an emittance around 0.04: it works precisely by refusing to radiate. The European patent’s official English title speaks of a material that can “reflect” far-infrared radiation. The word is used there in its everyday sense of sending radiation back; the physical mechanism, as measured, is absorption and re-emission.
eNOsyntex does the opposite. It absorbs the body’s radiation and re-radiates it, which is the mechanism the far-infrared textile literature describes. We publish emittance because it is what we measure, and because it is what governs the effect. For comparison, a commercial far-infrared polyamide yarn used in a published garment study is reported at ε = 0.88 over 5–20 µm (Loturco et al., 2016, see Sources).
A body at around 37 °C, with skin near 33 °C, radiates as a near-blackbody. That places the bulk of its emission in the thermal infrared, with a maximum close to 9.5 µm. About three quarters of that emission lies between 3 and 20 µm, the band in which we measure; most of the rest lies at longer wavelengths, up to about 50 µm.
That is why the charge is formulated for the thermal infrared rather than for the near infrared used by lamps and emitters. There is no external source to align with: the source is the wearer, and its spectrum is fixed by physics.
The charge is bound in the matrix rather than deposited on the surface, so durability depends on two things: the adhesion of the layer to the substrate, and the layer’s own cohesion under flex and abrasion. Both depend on the substrate, which is why we do not publish a single wash-cycle figure.
The protocol covers domestic washing (ISO 6330), coating mass loss, abrasion (ISO 12947, Martindale), rub fastness (ISO 105-X12) and flex. The question is not only whether the layer is still there, but whether it still performs: emittance is re-measured after ageing, and we report the cycle at which it falls below 0.90 rather than an average across the run.
For programmes with a defined service life, the protocol and the acceptance criteria are agreed with you before the prototype phase, and reported against.
Ceramic-loaded fibres carry their additive inside the filament. That limits the achievable charge and fixes it at spinning. The eNOsyntex charge is applied at finishing, so it can be placed exactly where the product needs it, and the zone map can change between product versions without re-engineering the yarn. The far-infrared yarns we have identified on the market carry a few per cent of mineral additive; the eNOsyntex coated zone carries at least 30 g/m².
Metallised and aluminised films are optically the opposite: low emittance, high reflectance. They also behave as a barrier: they change the hand, block moisture transfer and are visible in the construction. A printed pattern leaves the textile open between the coated zones.
We are happy to run a side-by-side characterisation against the material you currently specify, on your substrate, as part of feasibility.
It does not heat. In our own measurements on skin at 35 °C, temperature under the coating rose by about 0.1 °C, against about 2 °C under an aluminised survival blanket. It contains no energy source and adds no energy to the system: it changes the fate of radiation the body already emits. It does not release anything into or through the skin. And it does not, on its own, carry any claim about an effect on the body.
Whether a finished product incorporating the coating may claim an effect on the wearer is a question about that product, its intended purpose and its evidence, in its own regulatory framework. See Regulatory support.
eNOsyntex® is a textile coating technology supplied as a material and a process licence. It is not in itself a medical device. Figures on this page describe the optical and physical behaviour of the coating and are not claims of physiological or therapeutic effect.